10 75D2523The fireplace must be secured to the floor and/or to framing studs as shown in Figure 5 . Use two (2) wood screws or masonry/ concrete scre
75D2523 11CLEARANCESCLEARANCES TO COMBUSTIBLES MANTEL CLEARANCES NOTE: The combustible area around the fireplace must not protrude more than 1/2"
12 75D2523INSTALLATION PRECAUTIONSConsult local building codes before beginning the installation. The installer must make sure to select the proper v
75D2523 133"1"1"VENT INSTALLATION Figure 8 - Combustible Clearances for Vent Pipe A Minimum of 3" Clearance to the Top Is Require
14 75D2523VENT INSTALLATION OPTIONAL TOP VENT APPLICATION The appliance is shipped as a rear vent unit. If the installation layout requires the unit
75D2523 15VENT INSTALLATION INSTALLATION PLANNING There are two basic types of direct-vent installation: • Horizontal Termination • Vertical Terminat
16 75D2523VVVVVVVVDLEBCFBBBBBMIAAJHGAOperableFixedClosedFixedClosedOpera-bleKAAAGVENT INSTALLATION Figure 12 - Horizontal Vent Termination LocationVe
75D2523 17VGG = Combustible 24"(610mm) Noncombustible 18"(457mm)Combustible & NoncombustibleH = 24" (610mm)J = 20" (508mm)VH
18 75D2523Maximum20"101/2"(267mm)101/2"(267mm)81/2"(216mm)CombustibleWallNoncombustibleWallREAR WALL VENT INSTALLATION (5"X8
75D2523 19HOTHOTVENT INSTALLATION 4. Apply a bead of non-hardening mastic around the outside edge of vent cap. Position the vent cap in the center o
2 75D2523CONTENTSImportant Safety Information ... 3Product Features ... 5Code Appro
20 75D2523VENT INSTALLATION HORIZONTAL WITH VERTICAL RISE (THROUGH-THE-WALL) TERMINATION CONFIGURATIONSSince it is very important that the venting sy
75D2523 21HORIZONTAL (THROUGH-THE-WALL) TERMINATION CONFIGURATION (Continued)• If a 90° elbow is used in the horizontal vent run (level height main
22 75D2523101/2"(267mm)101/2"(267mm)81/2"(216mm)CombustibleWallNoncombustibleWall91/2"(241mm)91/2"(241mm)33/4"(92mm)71/
75D2523 23VENT INSTALLATION BELOW GRADE INSTALLATIONSWhen it is not possible to meet the required vent terminal clearances of 12" above grade le
24 75D2523VERTICAL THROUGH-THE-ROOF APPLICATIONS VENT INSTALLATION Figure 30 - Installing Restrictor Disc into Stove Collar RestrictorDiscStove Colla
75D2523 25Figure 32 - Maximum elbow Usage • Up to two 45° elbows may be used within the horizontal run. For each 45° elbow used on the horizontal p
26 75D2523101/2"101/2"VENT INSTALLATION INSTALLATION FOR VERTICAL TERMINATION 1. Determine the route your vertical venting will take. If c
75D2523 27ROOF PITCH H (feet)Flat to 6/12 1.0Over 6/12 to 7/12 1.25Over 7/12 to 8/12 1.5Over 8/12 to 9/12 2.0Over 9/12 to 10/12 2.5Over 10/12 to 11/1
28 75D2523Figure 37 - External Regulator with Vent Pointing Down (Propane/LP Only)FIREPLACE INSTALLATION CHECK GAS TYPEUse proper gas type for the fi
75D2523 293" MinimumFIREPLACE INSTALLATION A listed manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8&
75D2523 34. Never install the fireplace • in a recreational vehicle • where curtains, furniture, clothing, or other flammable objects are
30 75D2523CHECKING GAS PRES SURE1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is
75D2523 31ONOFFOPTIONAL REMOTERECEIVERONOFFRSPILOTHILOONOFFTHTPTH/TPONOFFOPTIONAL WALLSWITCHGRAYBLUEBLACKBLACKBLACKBLUEWHITERSREMOTE WALL MOUNTED SWI
32 75D2523#1 #2 #3 #4 #5 #6 7#Electronic ValveGRAY #7RED #2RED #2BLACK #4GREEN #6BLUE #1BLUEYELLOWYELLOWWHITE #3MAGENTA #515’ Wall Switch Wire BLACKW
75D2523 33CANOPY INSTALLATION AND GLASS REMOVAL Remove top louver assembly before installing canopy. 1. Unhook top louver assembly. Set aside. See F
34 75D2523BRICK INSTALLATIONBRICK INSTALLATION1. Install fl oor brick before installing logs or rock wool. 2. Install the rear brick panel by sliding
75D2523 35Continued Figure 45 - Rock Wool Placement on Rear of Burner. 1. Distribute one layer of rock wool to cover all round burner ports. Do not
36 75D2523Continued Figure 47 - Installing left middle logFigure 48 - Installing right middle log3. Place the left middle log by lining up the holes
75D2523 37LOG INSTALLATIONFigure 51 - Installing upper left logFigure 52 - Installing upper middle logFigure 53 - Installing upper right log7. Place
38 75D2523A. This appliance is equipped with a pilot which must be lit with built-in ignitor while following these instructions exactly.B. BEFORE O
75D2523 39PILOTOFFPILOTONContinued on next page OPERATING INSTRUCTIONS - MILLIVOLTAPPROVED LEAK TESTING METHOD You may check for gas leaks with the f
4 75D2523IMPORTANT SAFETY INFORMATIONContinued from page 312. Do not use this fireplace to cook food or burn paper or other objects.13. Never plac
40 75D252350PILOTOFFPILOTONOFFPILOTONPILOTFigure 56 - On Position PILOTOFFPILOTONFigure 55 - On/Off/RS Switch RSOFFONOPERATING INSTRUCTIONSMAIN BURNE
75D2523 41ONOFFPILOTLOHIFigure 59 - Electronic Gas Valve OPERATING INSTRUCTIONS - ELECTRONIC IGNITION LIGHTING ELECTRONIC IGNITION 1. STOP! Read t
42 75D2523Figure 60 - Pilot Flame Thermopile Thermocouple BURNER FLAMEThe flames from the burner should be visually checked as soon as the heater is
75D2523 43CLEANING AND MAINTENANCE VENT SYSTEMThe fireplace and venting system should be inspected before initial use and at least annually by a qual
44 75D2523VENT COMPONENTS FOR 4"X65/8" HOT13456789102ILLUSTRATED PARTS LIST 11ItemQty/Box DescriptionSimpson Duravent SelkirkMonessen P/
75D2523 45VENT COMPONENTS FOR 5"X8"HOT13456789102ILLUSTRATED PARTS LIST ItemQty/Box DescriptionSimpson Duravent SelkirkMonessen P/N1 1 Hori
46 75D2523153247106988ILLUSTRATED PARTS LISTSFIREBOX COMPONENTS
75D2523 47FIREBOX COMPONENTS ILLUSTRATED PARTS LISTS LOGS Item Description Qty MDV500 MDV600 Standard Features1 Junction Box Assembly 1 26D2128K 26D
48 75D2523ILLUSTRATED PARTS LISTSADDITIONAL ACCESSORIES1 2 3 4 5
75D2523 49ILLUSTRATED PARTS LISTS ADDITIONAL ACCESSORIES/FIELD INSTALLED OPTIONS AVAILABLE Item Description Qty MDV500 MDV600111Metal Trim - BrassMet
75D2523 5PRODUCT FEATURES AND CODE APPROVAL Off/Pilot/On Knob Optional Remote Receiver Figure 1 - MDV500 and MDV600 Fireplace (Millivolt Unit Shown
50 75D2523ILLUSTRATED PARTS LISTS123456710STANDING PILOT — MILLIVOLT CONTROL2T2I2C911,12, 13, 14, 15, 168
75D2523 51STANDING PILOT – MILLIVOLT CONTROLILLUSTRATED PARTS LISTS Item Description Qty MDV500NV MDV500PV MDV600NV MDV600PV1 Gas Valve Assembly 1 37
52 75D2523#1 #2 #3 #4 #5 #6 7#LOHIILLUSTRATED PARTS LISTS12345679ELECTRONIC IGNITION 81011
75D2523 53ELECTRONIC IGNITION ILLUSTRATED PARTS LISTSItem Description Qty MDV500NE MDV500PE MDV600NE MDV600PE1 Gas Valve Assembly 1 37D0016 37D0017 3
54 75D2523STANDING PILOT IGNITIONTROUBLESHOOTING SYMPTOM POSSIBLE CAUSE ACTION1. Spark ignitor will not light pilot after repeated triggering of piez
75D2523 55ELECTRONIC IGNITIONTROUBLESHOOTING START1. Turn gas supply off.2. Turn ON/OFF switch to “ON” Power to module (24V Normal)YES Is there a
56 75D2523NOTE REGARDING VENTED PRODUCTSThis product must be installed by a licensed plumber or gas fi tter when installed within the Commonwealth of
75D2523 57MASSACHUSETTS RESIDENTS ONLY2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above
58 75D2523NOTES
75D2523 59NOTES
6 75D2523PRE-INSTALLATION INFORMATIONINSTALLING ABOVE 2000 FEET• In the USA, the appliance must be derated 4% for every 1,000 ft above 2,000 ft elev
APRIL 2008 P/N 75D2523 • Rev. 2LIMITED LIFETIME WARRANTY POLICYLIFETIME WARRANTYThe following components are warranted for life to the original owner
75D2523 7BAHAECDFG1/2" or 5/8"1/2"or5/8"CAGCGA1/2" or 5/8"PRE-INSTALLATION INFORMATIONFIREPLACE FRAMINGFirebox framing
8 75D2523FB149/16"225/16"203/4"465/16"Ref. toFraming15/16"427/16"Ref. toWall345/8"toCenterof Pipe233/16"33/8&
75D2523 9YEABCDFYXPRE-INSTALLATION INFORMATION FIREPLACE LOCATIONPlan for the installation of your appliance. This includes determining where the un
Commentaires sur ces manuels