Monessen-hearth Direct Vent Gas Fireplace MDV500 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Four Monessen-hearth Direct Vent Gas Fireplace MDV500. Monessen Hearth Direct Vent Gas Fireplace MDV500 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 60
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
MDV SERIES
DIRECT VENT GAS FIREPLACE
INSTALLATION AND OPERATING
INSTRUCTIONS
MODELS: MDV500 and MDV600
READ BEFORE INSTALLING. SAVE THESE INSTRUCTIONS
WARNINGS
DUE TO HIGH TEMPERATURES, THE
APPLIANCE SHOULD BE LOCATED OUT OF
TRAFFIC AND AWAY FROM FURNITURE AND
DRAPERIES.
CHILDREN AND ADULTS SHOULD BE
ALERTED TO THE HAZARDS OF HIGH
SURFACE TEMPERATURE AND SHOULD
STAY AWAY TO AVOID BURNS OR CLOTHING
IGNITION.
YOUNG CHILDREN SHOULD BE SUPERVISED
WHEN THEY ARE IN THE SAME ROOM AS
THE APPLIANCE.
CLOTHING OR OTHER FLAMMABLE
MATERIAL SHOULD NOT BE PLACED ON
OR NEAR THE APPLIANCE.
KEEP THE ROOM AREA CLEAR AND
FREE FROM COMBUSTIBLE MATERIALS,
GASOLINE, AND OTHER FLAMMABLE
VAPORS AND LIQUIDS.
WARNINGS
IF THE INFORMATION IN THESE INSTRUCTIONS ARE
NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
WARNING: Improper installation, adjustment, alteration,
services or maintenance can cause injury or property
damage. Refer to this manual. For assistance or
additional information consult a qualified installer,
service agency or the gas supplier.
This appliance may be installed in an OEM installation
in manufactured home (USA only) or mobile home and
must be installed in accordance with the manufacturer's
instructions and the manufactured home construction
and safety standard, Title 24 CFR, Part 3280 or Standard
for Installation in Mobile Homes. CAN/CSA Z3-240MH.
This appliance is only for use with the type(s) of gas
indicated on the rating plate unless a certified kit is
used.
Vue de la page 0
1 2 3 4 5 6 ... 59 60

Résumé du contenu

Page 1 - MDV SERIES

MDV SERIES DIRECT VENT GAS FIREPLACEINSTALLATION AND OPERATING INSTRUCTIONSMODELS: MDV500 and MDV600READ BEFORE INSTALLING. SAVE THESE INSTRUCTIONSWAR

Page 2 - CONTENTS

10 75D2523The fireplace must be secured to the floor and/or to framing studs as shown in Figure 5 . Use two (2) wood screws or masonry/ concrete scre

Page 3 - IMPORTANT SAFETY INFORMATION

75D2523 11CLEARANCESCLEARANCES TO COMBUSTIBLES MANTEL CLEARANCES NOTE: The combustible area around the fireplace must not protrude more than 1/2"

Page 4

12 75D2523INSTALLATION PRECAUTIONSConsult local building codes before beginning the installation. The installer must make sure to select the proper v

Page 5 - Do not remove

75D2523 133"1"1"VENT INSTALLATION Figure 8 - Combustible Clearances for Vent Pipe A Minimum of 3" Clearance to the Top Is Require

Page 6 - PRE-INSTALLATION INFORMATION

14 75D2523VENT INSTALLATION OPTIONAL TOP VENT APPLICATION The appliance is shipped as a rear vent unit. If the installation layout requires the unit

Page 7

75D2523 15VENT INSTALLATION INSTALLATION PLANNING There are two basic types of direct-vent installation: • Horizontal Termination • Vertical Terminat

Page 8

16 75D2523VVVVVVVVDLEBCFBBBBBMIAAJHGAOperableFixedClosedFixedClosedOpera-bleKAAAGVENT INSTALLATION Figure 12 - Horizontal Vent Termination LocationVe

Page 9 - FIREPLACE LOCATION

75D2523 17VGG = Combustible 24"(610mm) Noncombustible 18"(457mm)Combustible & NoncombustibleH = 24" (610mm)J = 20" (508mm)VH

Page 10 - 75D2523

18 75D2523Maximum20"101/2"(267mm)101/2"(267mm)81/2"(216mm)CombustibleWallNoncombustibleWallREAR WALL VENT INSTALLATION (5"X8

Page 11 - CLEARANCES

75D2523 19HOTHOTVENT INSTALLATION 4. Apply a bead of non-hardening mastic around the outside edge of vent cap. Position the vent cap in the center o

Page 12 - INSTALLATION INFORMATION

2 75D2523CONTENTSImportant Safety Information ... 3Product Features ... 5Code Appro

Page 13 - VENT INSTALLATION

20 75D2523VENT INSTALLATION HORIZONTAL WITH VERTICAL RISE (THROUGH-THE-WALL) TERMINATION CONFIGURATIONSSince it is very important that the venting sy

Page 14 - 4"

75D2523 21HORIZONTAL (THROUGH-THE-WALL) TERMINATION CONFIGURATION (Continued)• If a 90° elbow is used in the horizontal vent run (level height main

Page 15

22 75D2523101/2"(267mm)101/2"(267mm)81/2"(216mm)CombustibleWallNoncombustibleWall91/2"(241mm)91/2"(241mm)33/4"(92mm)71/

Page 16

75D2523 23VENT INSTALLATION BELOW GRADE INSTALLATIONSWhen it is not possible to meet the required vent terminal clearances of 12" above grade le

Page 17 - HOW TO USE THE VENT GRAPH

24 75D2523VERTICAL THROUGH-THE-ROOF APPLICATIONS VENT INSTALLATION Figure 30 - Installing Restrictor Disc into Stove Collar RestrictorDiscStove Colla

Page 18 - VENTING INSTALLATION

75D2523 25Figure 32 - Maximum elbow Usage • Up to two 45° elbows may be used within the horizontal run. For each 45° elbow used on the horizontal p

Page 19 - 75D2523 19

26 75D2523101/2"101/2"VENT INSTALLATION INSTALLATION FOR VERTICAL TERMINATION 1. Determine the route your vertical venting will take. If c

Page 20

75D2523 27ROOF PITCH H (feet)Flat to 6/12 1.0Over 6/12 to 7/12 1.25Over 7/12 to 8/12 1.5Over 8/12 to 9/12 2.0Over 9/12 to 10/12 2.5Over 10/12 to 11/1

Page 21

28 75D2523Figure 37 - External Regulator with Vent Pointing Down (Propane/LP Only)FIREPLACE INSTALLATION CHECK GAS TYPEUse proper gas type for the fi

Page 22

75D2523 293" MinimumFIREPLACE INSTALLATION A listed manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8&

Page 23

75D2523 34. Never install the fireplace • in a recreational vehicle • where curtains, furniture, clothing, or other flammable objects are

Page 24

30 75D2523CHECKING GAS PRES SURE1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply is

Page 25

75D2523 31ONOFFOPTIONAL REMOTERECEIVERONOFFRSPILOTHILOONOFFTHTPTH/TPONOFFOPTIONAL WALLSWITCHGRAYBLUEBLACKBLACKBLACKBLUEWHITERSREMOTE WALL MOUNTED SWI

Page 26 - Continued on next page

32 75D2523#1 #2 #3 #4 #5 #6 7#Electronic ValveGRAY #7RED #2RED #2BLACK #4GREEN #6BLUE #1BLUEYELLOWYELLOWWHITE #3MAGENTA #515’ Wall Switch Wire BLACKW

Page 27

75D2523 33CANOPY INSTALLATION AND GLASS REMOVAL Remove top louver assembly before installing canopy. 1. Unhook top louver assembly. Set aside. See F

Page 28 - FIREPLACE INSTALLATION

34 75D2523BRICK INSTALLATIONBRICK INSTALLATION1. Install fl oor brick before installing logs or rock wool. 2. Install the rear brick panel by sliding

Page 29 - 3" Minimum

75D2523 35Continued Figure 45 - Rock Wool Placement on Rear of Burner. 1. Distribute one layer of rock wool to cover all round burner ports. Do not

Page 30 - CHECKING GAS PRES SURE

36 75D2523Continued Figure 47 - Installing left middle logFigure 48 - Installing right middle log3. Place the left middle log by lining up the holes

Page 31 - (Millivolt Units Only)

75D2523 37LOG INSTALLATIONFigure 51 - Installing upper left logFigure 52 - Installing upper middle logFigure 53 - Installing upper right log7. Place

Page 32 - ELECTRICAL INSTALLATION

38 75D2523A. This appliance is equipped with a pilot which must be lit with built-in ignitor while following these instructions exactly.B. BEFORE O

Page 33 - AND GLASS REMOVAL

75D2523 39PILOTOFFPILOTONContinued on next page OPERATING INSTRUCTIONS - MILLIVOLTAPPROVED LEAK TESTING METHOD You may check for gas leaks with the f

Page 34 - BRICK INSTALLATION

4 75D2523IMPORTANT SAFETY INFORMATIONContinued from page 312. Do not use this fireplace to cook food or burn paper or other objects.13. Never plac

Page 35 - 75D2523 35

40 75D252350PILOTOFFPILOTONOFFPILOTONPILOTFigure 56 - On Position PILOTOFFPILOTONFigure 55 - On/Off/RS Switch RSOFFONOPERATING INSTRUCTIONSMAIN BURNE

Page 36 - LOG INSTALLATION

75D2523 41ONOFFPILOTLOHIFigure 59 - Electronic Gas Valve OPERATING INSTRUCTIONS - ELECTRONIC IGNITION LIGHTING ELECTRONIC IGNITION 1. STOP! Read t

Page 37

42 75D2523Figure 60 - Pilot Flame Thermopile Thermocouple BURNER FLAMEThe flames from the burner should be visually checked as soon as the heater is

Page 38

75D2523 43CLEANING AND MAINTENANCE VENT SYSTEMThe fireplace and venting system should be inspected before initial use and at least annually by a qual

Page 39

44 75D2523VENT COMPONENTS FOR 4"X65/8" HOT13456789102ILLUSTRATED PARTS LIST 11ItemQty/Box DescriptionSimpson Duravent SelkirkMonessen P/

Page 40 - OPERATING INSTRUCTIONS

75D2523 45VENT COMPONENTS FOR 5"X8"HOT13456789102ILLUSTRATED PARTS LIST ItemQty/Box DescriptionSimpson Duravent SelkirkMonessen P/N1 1 Hori

Page 41 - TO TURN OFF GAS

46 75D2523153247106988ILLUSTRATED PARTS LISTSFIREBOX COMPONENTS

Page 42 - CLEANING AND MAINTENANCE

75D2523 47FIREBOX COMPONENTS ILLUSTRATED PARTS LISTS LOGS Item Description Qty MDV500 MDV600 Standard Features1 Junction Box Assembly 1 26D2128K 26D

Page 43

48 75D2523ILLUSTRATED PARTS LISTSADDITIONAL ACCESSORIES1 2 3 4 5

Page 44 - ILLUSTRATED PARTS LIST

75D2523 49ILLUSTRATED PARTS LISTS ADDITIONAL ACCESSORIES/FIELD INSTALLED OPTIONS AVAILABLE Item Description Qty MDV500 MDV600111Metal Trim - BrassMet

Page 45

75D2523 5PRODUCT FEATURES AND CODE APPROVAL Off/Pilot/On Knob Optional Remote Receiver Figure 1 - MDV500 and MDV600 Fireplace (Millivolt Unit Shown

Page 46 - ILLUSTRATED PARTS LISTS

50 75D2523ILLUSTRATED PARTS LISTS123456710STANDING PILOT — MILLIVOLT CONTROL2T2I2C911,12, 13, 14, 15, 168

Page 47

75D2523 51STANDING PILOT – MILLIVOLT CONTROLILLUSTRATED PARTS LISTS Item Description Qty MDV500NV MDV500PV MDV600NV MDV600PV1 Gas Valve Assembly 1 37

Page 48

52 75D2523#1 #2 #3 #4 #5 #6 7#LOHIILLUSTRATED PARTS LISTS12345679ELECTRONIC IGNITION 81011

Page 49

75D2523 53ELECTRONIC IGNITION ILLUSTRATED PARTS LISTSItem Description Qty MDV500NE MDV500PE MDV600NE MDV600PE1 Gas Valve Assembly 1 37D0016 37D0017 3

Page 50

54 75D2523STANDING PILOT IGNITIONTROUBLESHOOTING SYMPTOM POSSIBLE CAUSE ACTION1. Spark ignitor will not light pilot after repeated triggering of piez

Page 51

75D2523 55ELECTRONIC IGNITIONTROUBLESHOOTING START1. Turn gas supply off.2. Turn ON/OFF switch to “ON” Power to module (24V Normal)YES Is there a

Page 52 - #1 #2 #3 #4 #5 #6 7#

56 75D2523NOTE REGARDING VENTED PRODUCTSThis product must be installed by a licensed plumber or gas fi tter when installed within the Commonwealth of

Page 53

75D2523 57MASSACHUSETTS RESIDENTS ONLY2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above

Page 55

75D2523 59NOTES

Page 56 - SPECIAL REQUIREMENTS

6 75D2523PRE-INSTALLATION INFORMATIONINSTALLING ABOVE 2000 FEET• In the USA, the appliance must be derated 4% for every 1,000 ft above 2,000 ft elev

Page 57 - MASSACHUSETTS RESIDENTS ONLY

APRIL 2008 P/N 75D2523 • Rev. 2LIMITED LIFETIME WARRANTY POLICYLIFETIME WARRANTYThe following components are warranted for life to the original owner

Page 58

75D2523 7BAHAECDFG1/2" or 5/8"1/2"or5/8"CAGCGA1/2" or 5/8"PRE-INSTALLATION INFORMATIONFIREPLACE FRAMINGFirebox framing

Page 59 - 75D2523 59

8 75D2523FB149/16"225/16"203/4"465/16"Ref. toFraming15/16"427/16"Ref. toWall345/8"toCenterof Pipe233/16"33/8&

Page 60 - 877-406-9180

75D2523 9YEABCDFYXPRE-INSTALLATION INFORMATION FIREPLACE LOCATIONPlan for the installation of your appliance. This includes determining where the un

Commentaires sur ces manuels

Pas de commentaire