MHS, Inc.
This gas log set is to be installed only
in a solid-fuel burning replace with a
working ue constructed of noncombus-
tible material.
READ AND SAVE THESE INSTRUCTIONS
VENTED GAS LOG SET
INSTALLATION AND OPERATING
INSTRUCTIONS
Approved to ANSI Z21.60
MODELS: VWF18 VWF24 VWF30 VWF36
Natural Gas or Propane/LPG Control Type:
Manual and Milli-Volt
WARNINGS
IF THE INFORMATION IN THIS MANUAL IS NOT
FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY
RESULT CAUSING PROPERTY DAMAGE, PERSONAL
INJURY OR LOSS OF LIFE.
Do not store or use gasoline or other ammable
vapors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the re
department.
Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
Vue de la page 0
1 2 3 4 5 6 ... 55 56

Résumé du contenu

Page 1 - MHS, Inc

MHS, Inc.This gas log set is to be installed only in a solid-fuel burning fi replace with a working fl ue constructed of noncombus-tible material.READ

Page 2 - CONTENTS

10 27D8520CONNECTING THE GASPipe CouplingTo Gas Log Set or to Gas ValveShutoffValveGas Supply Inlet Figure 8 - Gas ConnectionPipeIMPORTANT: Hold appl

Page 3 - IMPORTANT SAFETY INFORMATION

27D8520 11Figure 9 - Pressure Test Point LocationTest PlugMANUAL CONTROL (Figure 9)The pressure regulator is preset and locked to discourage tamperin

Page 4 - SAFETY INFORMATION

12 27D8520LOG PLACEMENT FILLING THE BURNER PANFill the burner pan with vermiculite to the bottom of the rear log and sloped to the front edge of the b

Page 5 - CAUTION

27D8520 133. Place front left log #2 on the front of the grate and to the left. See Figure 13.4. Place front right log #3 on the front of the gra

Page 6

14 27D8520LOG PLACEMENT VWF24 MASSIVE OAK LOGS1. Slide shield plate down back of burner pan. See Figure 18. 2. Center rear log #1 on grate bars an

Page 7 - INSTALLATION

27D8520 15Figure 23 - Installing Right Side Middle Log (#5) and Left Top Log (#7) Figure 24 - Installing Right Top Log (#6)Right Side Middle Log (#5)

Page 8

16 27D8520LOG PLACEMENT VWF30 MASSIVE OAK LOGS (continued) 3. Place front left log #2 on the front of the grate and to the left. See Figure 27.4. Plac

Page 9 - WIRING (MILLI-VOLT)

27D8520 17LOG PLACEMENT VWF36 MASSIVE OAK LOGS1. Slide shield plate down back of burner pan. See Figure 34. 2. Center rear log #1 on grate bars a

Page 10 - CONNECTING THE GAS

18 27D8520LOG PLACEMENT Left Side Log (#6)Figure 39 - Installing Left Side Log (#6) Right Side Middle Log (#7) Figure 40 - Installing Right Side Middl

Page 11

27D8520 19LOG PLACEMENT VWF18 AMERICAN OAK LOGS1. Place Back Log #2 on grate bars on back of grate. See Figure 46.2. Place Front Log #1 on front

Page 12 - LOG PLACEMENT

2 27D8520CONTENTSImportant Safety Information ...3Product Specifi cations ...4Getting Starte

Page 13

20 27D8520LOG PLACEMENT VWF24 AMERICAN OAK LOGS1. Place Back Log #2 on grate bars on back of grate. See Figure 52.2. Place Front Log #1 on front o

Page 14

27D8520 21LOG PLACEMENT VWF30 AMERICAN OAK LOGS1. Place Back Log #2 on grate bars on back of grate. See Figure 58.2. Place Front Log #1 on front

Page 15

22 27D8520VWF30 AMERICAN OAK LOGS (continued) 7. Place Left Crossover Log #7 on Log #2 and Log #5. See Figure 64.8. Place Right Crossover Log #8 o

Page 16

27D8520 23LOG PLACEMENT 1. Slide shield plate down back of burner pan. See Figure 65. 2. Place Back Log #1 on grate bars on back of grate. See F

Page 17

24 27D8520LOG PLACEMENTShield Plate MODELS VWF24/18 SPLIT RIVER OAK1. Slide shield plate down back of burner pan. See Figure 67. 2. Place Back Log

Page 18

27D8520 25MODELS VWF24/18 SPLIT RIVER OAK (continued)5. Rest right end of Top Right Log #4 on bottom right log. See Figure 72. 7. Place end of

Page 19

26 27D8520LOG PLACEMENT Shield Plate MODELS VWF30/24 SPLIT RIVER OAK1. Slide shield plate down back of burner pan. See Figure 75. 2. Place Back Lo

Page 20

27D8520 27LOG PLACEMENT MODELS VWF30/24 SPLIT RIVER OAK (continued) 6. Rest Bottom Left Log #5 on back log #1 and to the outside of the left grat

Page 21

28 27D8520LOG PLACEMENT MODELS VWF36/30 SPLIT RIVER OAK1. Slide shield plate down back of burner pan. See Figure 83. 2. Place Back Log #1 on back

Page 22

27D8520 29LOG PLACEMENT MODELS VWF36/30 SPLIT RIVER OAK (continued) 6. Rest Bottom Left Log #5 on back log #1 and to the outside of the left grat

Page 23

27D8520 3INSTALLERPlease leave these instructions with the appliance.OWNERPlease retain these instructions for future reference.IMPORTANT SAFETY INFO

Page 24

30 27D8520LOG PLACEMENT MODELS VWF18 SPLIT PINE1. Slide shield plate down back of burner pan. See Figure 92. 2. Place Left Front Log #1A on front

Page 25

27D8520 31LOG PLACEMENT MODELS VWF18 SPLIT PINE (continued) 6. Rest front end of Right Log #6 on right top of Log #1B. The back end of Log #6 rest

Page 26

32 27D8520LOG PLACEMENT MODELS VWF24 SPLIT PINE1. Slide shield plate down back of burner pan. See Figure 101. 2. Place Left Front Log #1A on front

Page 27

27D8520 33LOG PLACEMENT MODELS VWF24 SPLIT PINE (continued) 6. Rest front end of Right Log #4 on right top of Log #1B. The back end of Log #4 rest

Page 28

34 27D8520LOG PLACEMENT Figure 111 - Sliding Shield Plate Down Back of Burner Pan Burner Pan Shield Plate MODELS VWF30 SPLIT PINE1. Slide shield pla

Page 29

27D8520 35LOG PLACEMENT MODELS VWF30 SPLIT PINE (continued) 6. Rest front end of Right Log #4 on right top of Log #1B. The back end of Log #4 rest

Page 30

36 27D8520LOG PLACEMENT Figure 122 - Sliding Shield Plate Down Back of Burner Pan Burner Pan Shield Plate MODEL VWF24/18WP WEATHERED PINE LOG1. Slid

Page 31

27D8520 37LOG PLACEMENT Figure 127 - Placing Top Left Log (#5) behind Rear Log Top Left Log (#5) Mid Front Log (#6) Figure 128 - Placing Mid Front Lo

Page 32

38 27D8520LOG PLACEMENT Figure 129 - Sliding Shield Plate Down Back of Burner Pan Burner Pan Shield Plate MODEL VWF30/24WP WEATHERED PINE LOG1. Slid

Page 33

27D8520 39LOG PLACEMENT MODEL VWF30/24WP WEATHERED PINE LOG (continued) 6. Place Top Left Log #5 behind Rear Log #1 on the notch on rear left of gr

Page 34

4 27D8520The manifold pressure for propane is 10" WC.The manifold pressure for natural is 4"WC. The minimum inlet gas supply pressure is 4&

Page 35

40 27D8520LOG PLACEMENT Figure 137 - Sliding Shield Plate Down Back of Burner Pan Burner Pan Shield Plate MODEL VWF36/30WP WEATHERED PINE LOG1. Slid

Page 36

27D8520 41LOG PLACEMENT MODEL VWF36/30WP WEATHERED PINE LOG (continued) 6. Place Top Left Log #5 behind Rear Log #1 on the notch on rear left of g

Page 37

42 27D8520OPERATING INSTRUCTIONSSAFETY INSTRUCTION FOR MANUAL CONTROL (SPK)1. STOP! Read the safety information label.2. Make sure the manual shuto

Page 38

27D8520 43ONOFFPIILOTOPERATING INSTRUCTIONS 1. STOP! Read the safety information label.2. Make sure the manual shutoff valve is fully open.3. Tur

Page 39

44 27D8520FLAME APPEARANCE CHECKING BURNER FLAMESFlame should be yellow and extend vertically (not curling toward fireplace screen).Figure 151 - Pilo

Page 40

27D8520 45FIREPLACE DRAFT TESTIMPORTANT: Fireplace Draft Test During Initial InstallationIt is critical to verify that your chimney is drafting prope

Page 41

46 27D8520The remote control receiver and batteries are very sensitive to heat. Exposure to high temperatures can cause the receiver to malfunction a

Page 42 - TO TURN OFF GAS TO HEATER

27D8520 4725REPLACEMENT PARTS ASSEMBLY Item DescriptionVWF(18,24,30,36)NMVWF(18,24,30,36)PMVWF(18,24,30,36)NVVWF(18,24,30,36)PV1 Injector 27D7022 27D

Page 43

48 27D8520 1 2 3 4 5 7 6 81067981154213REPLACEMENT PARTSMASSIVE OAK LOGSItem Description Qty. VWF18MO VWF24MO VWF30MO1 Back Log 1 27D7500 27D750

Page 44 - FLAME APPEARANCE

27D8520 49 1 3 4 5 6 7 2 8 1 2 3 4 5 6BIRCH LOGS AMERICAN OAK LOGS REPLACEMENT PARTS Item Description Qty. VWF18AO VWF24AO VWF30AO1 Front Log 1 27D85

Page 45 - FIREPLACE DRAFT TEST

27D8520 5 CHIMNEY HEIGHT FLUE OPENING 6' 64 sq in 8' 64 sq in 10' 64 sq in 15' 51 sq in 20' 51 sq in 30' 5

Page 46 - CLEANING AND SERVICING

50 27D8520 1 2 34 56 7 8 REPLACEMENT PARTS SPLIT RIVER OAK LOGS Item Description Qty. VWF24/18SRO VWF30/24SRO VWF36/30SRO1 Front Log 1 27D8800 27D88

Page 47 - REPLACEMENT PARTS

27D8520 51 1A 1B 1A 1B 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 REPLACEMENT PARTS SPLIT PINE LOGS Item Description Qty.VWF18SPA VWF24SPA VWF30SP

Page 48

52 27D8520WEATHERED PINE LOGS Item Description Qty VWF24/18WP1Rear Log127D51402Bottom Right Log127D51413Bottom Left Log127D51424Top Right Log127D51435

Page 49

27D8520 53NOTE REGARDING VENTED PRODUCTSThis product must be installed by a licensed plumber or gas fi tter when installed within the Commonwealth of

Page 50

SPECIAL REQUIREMENTS CONTINUED2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisio

Page 51

27D8520 55NOTES

Page 52

LIMITED LIFETIME WARRANTY POLICYLIFETIME WARRANTYThe following components are warranted for life to the original owner, subject to proof of purchase:

Page 53 - SPECIAL REQUIREMENTS

6 27D8520 Height of Restriction (X) Minimum Depth of Fireplace/Firebox No restriction 13" Manual Control 131/2" Milli-Volt Control

Page 54

27D8520 7Damper StopDamperInjector (Natural Gas only)FOR MASSACHUSETTS RESIDENTS ONLYInstallation of this vented gas log set in the Commonwealth of M

Page 55 - 27D8520 55

8 27D8520Covers must be installed prior to operation to prevent overheating. WARNINGGrate bar must not touch the valve.NOTICEFigure 5 - Placing Cover

Page 56 - BASIC WARRANTY

27D8520 9Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper oper

Modèles reliés VWF18 | VWF36 |